Electronic Surge Protection
Surge Protector ESP 240 M1
Application:
AC Power
Type:
Combined Type 1-3
Current:
-
Phase:
Single Phase
Let through Voltage (Up):
600V
Voltage:
240V
In-line Resistance:
-
Installation:
Service entrance - after meter Main Distribution Board or sub-distribution board. Flat mounting
Description:
Combined Type 1, 2 and 3 tested protector (to BS EN 61643) for use on mains
power distribution systems primarily to protect connected electronic equipment from transient overvoltages on the mains supply, e.g. computer, communications or control equipment. For use at boundaries up to LPZ 0 to protect against flashover (typically the main distribution board location, with multiple metallic services entering) through to LPZ 3 to protect sensitive electronic equipment.
Surge Protector ESP 240/I/TNS
Application:
AC Power
Type:
Combined Type 1-2
Current:
-
Phase:
Single Phase
Let through Voltage (Up):
1400V
Voltage:
240V
In-line Resistance:
-
Installation:
Service entrance - after meter Main Distribution Board or sub-distribution board. DIN rail mounting
Description:
Combined Type 1 and 2 tested protector (to BS EN 61643) for use on the main
distribution board, particularly where a structural Lightning Protection System (LPS) is employed, for equipotential bonding. For use at boundaries up to LPZ 0 to protect against flashover (typically the main distribution board location) through to LPZ 2 to protect electrical equipment from damage.
Surge Protector ESP 415 M1
Application:
AC Power
Type:
Combined Type 1-3
Current:
-
Phase:
3 Phase
Let through Voltage (Up):
600V
Voltage:
415V
In-line Resistance:
-
Installation:
Service entrance - after meter Main Distribution Board or sub-distribution board. Flat mounting
Description:
Combined Type 1, 2 and 3 tested protector (to BS EN 61643) for use on mains
power distribution systems primarily to protect connected electronic equipment from transient overvoltages on the mains supply, e.g. computer, communications or control equipment. For use at boundaries up to LPZ 0 to protect against flashover (typically the main distribution board location, with multiple metallic services entering) through to LPZ 3 to protect sensitive electronic equipment.
Surge Protector ESP 415 M2
Application:
AC Power
Type:
Combined Type 1-3
Current:
-
Phase:
3 Phase
Let through Voltage (Up):
600V
Voltage:
415V
In-line Resistance:
-
Installation:
Service entrance - after meter Main Distribution Board or sub-distribution board. Flat mounting
Description:
Combined Type 1, 2 and 3 tested protector (to BS EN 61643) for use on the main distribution board directly feeding electronic equipment such as computers, communication and control equipment, particularly where a structural Lightning Protection System (LPS) is employed. For use at boundaries up to LPZ 0 to protect against flashover (typically the main distribution board location) through to LPZ 3 to protect sensitive electronic equipment.
Surge Protector ESP 415 D1
Application:
AC Power
Type:
Combined Type 1-3
Current:
-
Phase:
3 Phase
Let through Voltage (Up):
600V
Voltage:
415V
In-line Resistance:
-
Installation:
Service entrance - after meter Main Distribution Board or sub-distribution board. DIN rail mounting
Description:
Combined Type 1, 2 and 3 tested protector (to BS EN 61643) for use on three
phase mains power distribution systems primarily to protect connected electronic equipment from transient overvoltages on the mains supply, e.g. computer, communications or control equipment. Innovative remote display options allow both protector and display to be mounted in their optimum position. For use at boundaries up to LPZ 0 to protect against flashover (typically the main distribution board location, with multiple metallic services entering) through to LPZ 3 to protect sensitive electronic equipment.
Surge Protector ESP 415/I/TNS
Application:
AC Power
Type:
Combined Type 1-2
Current:
-
Phase:
3 Phase
Let through Voltage (Up):
1400V
Voltage:
415V
In-line Resistance:
-
Installation:
Service entrance - after meter Main Distribution Board or sub-distribution board. DIN rail mounting
Description:
Combined Type 1 and 2 tested protector (to BS EN 61643) for use on the main
distribution board, particularly where a structural Lightning Protection System (LPS) is employed, for equipotential bonding. For use at boundaries up to LPZ 0 to protect against flashover (typically the main distribution board location) through to LPZ 2 to protect electrical equipment from damage.